SINGH’S INDEX ACCURACY WITH DEXA SCAN FOR EVALUATION OF OSTEOPOROSIS
Keywords:
Singh index, DEXA scan, osteoporosisAbstract
Objective: To compare Singh’s index accuracy versus DEXA scan in diagnosing osteoporosis in post-menopausal
women.
Material & Methods: This was a cross-sectional study, conducted in the Department of Orthopaedics, Northwest
General Hospital & Research Centre, Peshawar, Pakistan, involving 120 post-menopausal women at Northwest General
Hospital & Research Centre, Peshawar, from June 2015 to December 2015. All patients had X-ray Pelvis and DEXA
scan was done.
Results: There was ‘slight agreement’ between DEXA scan and Singh Index on the basis of Kappa statistics (.088).
Mean age was 62.91 ± 9.6 SD. Chi-square value was 1.106, p-value was 0.293 which was not significant.
Conclusion: Singh index assessment for osteoporosis is not reliable and can not be a valid substitute for DEXA scan.
Downloads
Published
How to Cite
Issue
Section
License
All articles published in the Journal of Medical Sciences (JMS) are licensed under the Creative Commons Attribution 4.0 International License (CC-BY 4.0). Under the CC BY 4.0 license, author(s) retain the ownership of the copyright publishing rights without restrictions for their content, and allow others to copy, use, print, share, modify, and distribute the content of the article even for commercial purposes as long as the original authors and the journal are properly cited. No permission is required from the author/s or the publishers for this purpose. Appropriate attribution can be provided by simply citing the original article. The corresponding author has the right to grant on behalf of all authors, a worldwide license to JMS and its licensees in all forms, formats, and media (whether known now or created in the future), The corresponding author must certify and warrant the authorship and proprietorship and should declare that he/she has not granted or assigned any of the article’s rights to any other person or body.
The corresponding author must compensate the journal for any costs, expenses, or damages that the JMS may incur as a result of any breach of these warranties including any intentional or unintentional errors, omissions, copyright issues, or plagiarism. The editorial office must be notified upon submission if an article contains materials like text, pictures, tables, or graphs from other copyrighted sources. The JMS reserves the right to remove any images, figures, tables, or other content, from any article, whether before or after publication, if concerns are raised about copyright, license, or permissions and the authors are unable to provide documentation confirming that appropriate permissions were obtained for publication of the content in question.